230V occupancy sensors: The straightforward way to energy savings & comfort

Occupancy sensors are very sensitive PIR (passive infrared) motion sensors.

In many applications, 230V presence detectors with built-in relays are the quickest and simplest way to achieve major energy savings and comfort improvements with little effort.  
 
It doesn't matter whether you want to implement energy optimisations quickly and inexpensively in existing buildings, or whether you prefer to rely on proven 230V technology instead of complex and expensive smarthome systems in new buildings: The ecos 230V presence detectors are the right choice. You will find reliable, small ceiling-mounted presence detectors with a good price/performance ratio.

Typical applications:

  • Offices
  • Meeting rooms
  • Corridors / hallways
  • Living rooms
  • Classrooms
  • Bathrooms and toilet areas

Why is a high switching capacity so important? 

Today, LED loads are predominantly switched. Unfortunately, these are often characterised by extremely high inrush currents. These current peaks usually exceed the value of the current during operation many times over. 
 
The 230V presence detectors offer you an extremely high switching capacity due to the built-in high-performance relay. They therefore switch the connected loads directly. Phase L and neutral conductor go to the detector. The switched phase L' goes from the detector to the luminaires. 
 
Even "difficult" capacitive loads such as LED luminaires can be switched reliably in the long term. 
 
All 230V EPV presence detectors are always supplied including a WAGO connection plug with strain relief and terminal cover. This makes installation easier for you in many cases because L, N and L' are connected to the WAGO plug and not directly to the back of the detector. The ready-wired plug is then only plugged into the presence detector.
 
For the models with 1-10V DIM function, the plug set also includes a 1-10V WAGO plug.

Comparison BEG / Ecos  Comparison Esylux / Ecos / BEG  Comparison Analog / Digital  Comparison  BEG Comparison          

Electrical connection of ecos 230V occupancy sensors                              

This will in many cases simplefy the installation because L, N and L are connected to the WAGO plug and not directly to the occupancy sensor. Only the wired WAGO plug will be inserted into the sensor. Apart from a good strain relief for the wiring it provides protection against touching the terminals. Electrical Connection of 230V Sensors

For models with dimming function, the WAGO plug set also incudes a 1-10V plug.

As a project solution, we also offer pre-cabling in "Wieland" or "Winsta" format on request. Please contact us at [email protected].

Elektrischer Anschluss ecos PM/230V Präsenzmelder

Installation & Accessories (ceiling mounting)

Option 1: Flush mounting into false, partitioned ceilings (e.g. ceiling tiles)

This is the easiest and quickest installation option. Each sensor comes with a white plastic clip which fits onto the sensor body from behind. It then holds the sensor firmly in place. To accomodate a wide range of ceiling thicknesses, the ring can be placed onto the sensor body in both directions. This installation type requires that you can actually reach the rear of the sensor with one hand. This standard clip is always supplied with each sensor.

Ceiling installationOccupancy sensor with clipOccupancy sensor in ceiling

Link: Installation dimensions of ecos occupancy sensors

Option 2: Flush mounting in suspended non-partitioned ceilings, e.g. plasterboard ceilings

When you can not reach around to the rear of the sensor in order to slide the plastic holding ring on, the sensor can instead be mounted with an additional ceiling clip ring with two springs. The sensor is inserted into this ring following the electrical installation.

ecos spring clipSpring clip with ecos

Link: Data sheet for spring clip

Option 3: Surface mounting enclosure

Where flush mounting is impossible, for example on bare concrete ceilings, the surface mounting enclosure is the best option.

surface mounting enclosuresurface mounting enclosure with ecos

Link: Data sheet for surface mounting enclosure

Option 4: Installation in concrete canisters

In new buildings with concrete ceilings, the ecos sensors can be installed in concrete canisters. We can offer cover caps for this application. Please contact us for more details: [email protected].

Filters
ecos
Occupancy Sensor ecos PM/230V/5T
Occupancy sensor with adjustable delay time (no light sensor). Two variations available. This sensor reacts to presence - regardless of how bright the room is. In two variations available, up to 12 meter intallation height.
* €99,90 * SRP
(€118,88 Incl. tax)
ecos
Occupancy Sensor ecos PM230V/5L
Small "Allround" occupancy sensor with adjustable delay time and adjustable twilight level switch. Two variations available. Perfect for retrofitting existing non-dimmable lighting. Superior sensitivity due to digiPIR technology. Made in Germany.
* €101,50 * SRP
(€120,79 Incl. tax)
ecos
Occupancy Sensor ecos PM/230V/12T
Occupancy sensor with adjustable delay time (no light sensor). Two variations available. This sensor reacts to presence - regardless of how bright the room is. In two variations available, up to 12 meter intallation height.
* €105,90 * SRP
(€126,02 Incl. tax)